Iron coated with zinc by cleaning and immersion in melted zinc. The iron is prevented from rusting by galvanic action. It forms the negative element in a couple of which the zinc is the positive element. From this electric protective action the name is derived.

Galvano-cautery, Chemical.

Electro-therapeutic treatment with sharp electrodes, one of which is inserted in the tissue and a current pa.s.sed by completing the circuit through the tissue so as to electrolyze or decompose the fluids of the tissue. It is applied in the removal of hair or extirpation of the follicle. The process is not one of heating, and is improperly named cautery.

Galvano-faradization.

In medical electricity the application of the voltaic and induced or secondary current simultaneously to any part of the system.

Galvanometer.

An instrument for measuring current strength and sometimes for measuring inferentially potential difference, depending on the action of a magnetic field established by the current, such action being exerted on a magnetic needle or its equivalent.

A current pa.s.sing through a conductor establishes circular lines of force. A magnetic needle placed in their field is acted on and tends to place itself parallel with the lines, in accordance with the principles of current induction. (See Induction, Electro-magnetic.) A common compa.s.s held near a conductor through which a current is pa.s.sing tends to place itself at right angles to such conductor. For a maximum effect the conductor or the part nearest the needle should lie in the magnetic meridian. If at right angles thereto its action will only strengthen the directive force of the earth"s induction or magnetic field, as the needle naturally points north and south. Such combination is virtually a galvanometer.

266 STANDARD ELECTRICAL DICTIONARY.

A typical galvanometer comprises a flat coil of wire placed horizontally within which a magnetic needle is delicately poised, so as to be free to rotate with the least possible friction. The needle may be supported on a sharp point like a compa.s.s needle, or may be suspended by a long fine filament. It should be covered by a gla.s.s plate and box, or by a gla.s.s shade. Finally a graduated disc may be arranged to show the amount of deflection of the needle.

In use the apparatus is turned about until the needle, as acted on by the earth"s magnetic field, lies parallel to the direction of the coils of wire. On pa.s.sing a current through the coil the needle is deflected, more or less, according to its strength.

By using exceedingly fine wire, long enough to give high resistance, the instrument can be used for very high potentials, or is in condition for use in determining voltage. By using a coil of large wire and low resistance it can be employed in determining amperage. In either case the deflection is produced by the current.

The needle is often placed above or below the coil so as only to receive a portion of its effect, enough for all practical purposes in the commoner cla.s.s of instruments.

The galvanometer was invented by Schweigger a short time after Oersted"s discovery, q. v.

Galvanometer, Absolute.

A galvanometer giving absolute readings; properly one whose law of calibration can be deduced from its construction. Thus the diameter of the coil, and the constants and position of a magnetic needle suspended in its field being known, the current intensity required to deflect the needle a given number of degrees could be calculated.

Galvanometer, Aperiodic.

A galvanometer whose needle is damped (see Damping) as, for instance, by the proximity of a plate of metal, by an air vane or otherwise, so that it reaches its reading with hardly any oscillation. A very light needle and a strong magnetic field also conduce to vibrations of short period dying out very quickly. Such galvanometers are termed "dead-beat." No instrument is absolutely dead-beat, only relatively so.

267 STANDARD ELECTRICAL DICTIONARY.

Fig. 178. ASTATIC GALVANOMETER.

Galvanometer, Astatic.

A galvanometer with a pair of magnetic needles connected astatically, or parallel with their poles in opposition. (See Astatic Needle.) Each needle has its own coil, the coils being wound in opposite directions so as to unite in producing deflections in the same sense. As there should be some directive tendency this is obtained by one of the magnets being slightly stronger than the other or by the proximity of a fixed and adjustable controlling magnet, placed nearer one needle than the other.

For small deflections the currents producing them are proportional to their extent.

Galvanometer, Ballistic.

A galvanometer whose deflected element has considerable moment of inertia; the exact opposite of an aperiodic or dead beat galvanometer.

(See Galvanometer, Aperiodic.) All damping by air vanes or otherwise must be carefully done away with.

Fig. 179. SIEMENS & HALSKE"S GALVANOMETER.

Siemens & Halske"s galvanometer is of the reflecting or mirror type (see Galvanometer, Reflecting) with suspended, bell-shaped magnet, in place of the ordinary magnetic needle, or astatic combination of the lightest possible weight in the regular instrument. A copper ball drilled out to admit the magnet is used as damper in the ordinary use of the instrument. To convert it into a ballistic galvanometer the copper ball is removed. The heavy suspended magnet then by its inertia introduces the desired element into the instrument.

268 STANDARD ELECTRICAL DICTIONARY.

Referring to the cut, Fig. 179, M is the suspended magnet, with north and south poles n and s; S is the reflecting mirror; r is the tube containing the suspending thread; R is the damper removed for ballistic work.

The ballistic galvanometer is used to measure quant.i.ties of electricity in an instantaneous discharge, which discharge should be completed before the heavy needle begins to move. The extreme elongation or throw of the needle is observed, and depends (1) on the number of coulombs (K) that pa.s.s during the discharge; (2) on the moment of inertia of the needle and attached parts; (3) on the moment of the controlling forces, i. e., the forces tending to pull the needle back to zero; (4) on the moment of the damping forces; (5) on the moment of the deflecting forces due to a given constant current. The formula is thus expressed:

K = (P / PI ) * A * sin( k? / 2 ) / tan( a? )

in which K = coulombs discharged; P = periodic time of vibration of needle; A = amperes producing a steady deflection equal to a? ; k? = first angular deflection of needle. For accuracy k? and a? should both be small and the damping so slight as to be negligible. Otherwise a correction for the latter must be applied. For approximate work for k?

and a? the deflections read on the scale may be used with the following formula:

K = (P / PI ) * ( A / 2 ) * ( k? / a? )

Galvanometer Constant.

a.s.sume a galvanometer with a very short needle and so placed with respect to its coils that the magnetic field produced by a current circulating in them is sensibly uniform in the neighborhood of the needle, with its lines of force at right angles thereto. The field is proportional to the current i, so that it may be denoted by G i. Then G is the galvanometer constant. If now the angle of deflection of the needle is ? against the earth"s field H, M being the magnetic moment of the needle we have G i M cos ? = H M sin ? or i = (H/G)* tan ?. H/G is the reduction factor; variable as H varies for different places.

For a tangent galvanometer the constant G is equal to 2*PI*(n/a), in which n denotes the number of turns of wire, and a denotes the radius of the circle.

Galvanometer, Differential.

A galvanometer in which the needle is acted on by two coils wound in opposition, each of equal deflecting action and of equal resistance. If a current is divided between two branches or parallel conductors, each including one of the coils, when the needle points to zero the resistances of the two branches will bc equal. In the cut, C C"

represent the coils, and A and B the two leads into which the circuit, P Q, is divided.

269 STANDARD ELECTRICAL DICTIONARY.

Fig. 180. THEORY OF DIFFERENTIAL GALVANOMETER.

Fig. 181. DIFFERENTIAL GALVANOMETER.

Galvanometer, Direct Reading.

A calibrated galvanometer, whose scale is graduated by volts or amperes, instead of degrees.

© 2024 www.topnovel.cc